Shipboard Cable
Type "T/N" Signal Cable Power Distribution Unarmored
| Part Number |
AWG | Conductors | Stranding | Insulation | Jacket | Diameter | Description | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| AWG | MM2 | IN | MM | IN | MM | IN | MM | ||||
| MD-DNI-10 | 10 | 5.26 | 2 | 7/38.5 | 0.020 | 0.51 | 0.045 | 1.14 | 0.430 | 10.92 | 2C 10 AWG Type N |
| MD-DNI-16 | 8 | 8.37 | 2 | 7/48.6 | 0.030 | 0.76 | 0.060 | 1.52 | 0.580 | 14.73 | 2C 8AWG Type N |
| MD-DNI-26 | 6 | 13.3 | 2 | 7/61.2 | 0.030 | 0.76 | 0.060 | 1.52 | 0.650 | 16.51 | 2C 6AWG Type N |
| MD-DNI-3 | 16 | 1.31 | 2 | 7/19.2 | 0.019 | 0.48 | 0.045 | 1.14 | 0.300 | 7.62 | 2C 16AWG Type N |
| MD-DNI-6 | 12 | 3.31 | 2 | 7/30.5 | 0.015 | 0.38 | 0.045 | 1.14 | 0.370 | 9.4 | 2C 12AWG Type N |
| MD-FNI-16 | 8 | 8.37 | 4 | 7/48.6 | 0.030 | 0.76 | 0.060 | 1.52 | 0.660 | 16.76 | 4C 8AWG Type N |
| MD-FNI-3 | 16 | 1.31 | 4 | 7/19.2 | 0.019 | 0.48 | 0.045 | 1.14 | 0.340 | 8.64 | 4C 16AWG Type N |
| MD-FNI-4 | 14 | 2.08 | 4 | 7/24.2 | 0.015 | 0.38 | 0.045 | 1.14 | 0.390 | 9.91 | 4C 14AWG Type N |
| MD-FNI-6 | 12 | 3.31 | 4 | 7/30.5 | 0.015 | 0.38 | 0.045 | 1.14 | 0.430 | 10.92 | 4C 12AWG Type N |
| MD-MNI-10-3 | 16 | 1.31 | 10 | 7/19.2 | 0.019 | 0.48 | 0.045 | 1.14 | 0.500 | 12.7 | 10C 16AWG Type N |
| MD-MNI-7-4 | 14 | 2.08 | 7 | 7/24.2 | 0.019 | 0.48 | 0.045 | 1.14 | 0.440 | 11.18 | 7C 14AWG Type N |
| MD-TNI-10 | 10 | 5.26 | 3 | 7/38.5 | 0.020 | 0.51 | 0.045 | 1.14 | 0.460 | 11.68 | 3C 10AWG Type N |
| MD-TNI-16 | 8 | 8.37 | 3 | 7/48.6 | 0.030 | 0.76 | 0.060 | 1.52 | 0.610 | 15.49 | 3C 8AWG Type N |
| MD-TNI-6 | 12 | 3.31 | 3 | 7/30.5 | 0.015 | 0.38 | 0.045 | 1.14 | 0.390 | 9.91 | 3C 12AWG Type N |
Applications
Cobra’s Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
Features
- IEEE & ABS APPROVED
Construction
- CONDUCTORS - Soft annealed bare copper per ASTM B3 and B8, stranded as shown.
- INSULATION - Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998), IEEE 1580 (2001) and UL1309/CSA 245. Thickness as shown. Insulated conductors are rated VW-1
- JACKET - Flame retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core, (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45 (1998) and UL 1309/CSA 245.
![]() |
![]() |
![]() |
![]() |
|
UL Listed |
CSA |
ABS Approved |
IEEE |