Shipboard Cable
Type "T/N" Signal Cable Power Distribution Unarmored
Individual & Overall Shielded Twisted Pair

Part
Number
AWG Conductors Stranding Insulation Jacket Diameter Description
AWG MM2 IN MM IN MM IN MM
MD-TPS16TIU-2 16 1.31 2 7/19.2 0.015 0.38 0.045 1.14 0.430 10.92 2PR 16AWG Type N
MD-TPS18TIU-1 18 .82 1 7/15.2 0.015 0.38 0.045 1.14 0.270 6.86 1PR 18AWG Type N
MD-TPS18TIU-2 18 .82 2 7/15.2 0.015 0.38 0.045 1.14 0.390 9.91 2PR 18AWG Type N
MD-TPS18TIU-3 18 .82 3 7/15.2 0.015 0.38 0.045 1.14 0.420 10.67 3PR 18AWG Type N
MD-TPS18TIU-8 18 .82 8 7/15.2 0.015 0.38 0.060 1.52 0.620 15.75 8PR 18AWG Type N

 

Applications

Cobra’s Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.

Features

  • IEEE & ABS APPROVED

 

Construction

  • CONDUCTORS - Soft annealed bare copper per ASTM B3 and B8, stranded as shown.
  • INSULATION - Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998), IEEE 1580 (2001) and UL1309/CSA 245. Thickness as shown. Insulated conductors are rated VW-1.
  • PAIR SHIELD - Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over twisted pair, covered with a polyester tape.
  • JACKET - Flame retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core, (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45 (1998) and UL 1309/CSA 245.