Shipboard Cable
Type "T/N" Signal Cable Power Distribution Unarmored
Individual & Overall Shielded Twisted Pair
| Part Number |
AWG | Conductors | Stranding | Insulation | Jacket | Diameter | Description | ||||
|---|---|---|---|---|---|---|---|---|---|---|---|
| AWG | MM2 | IN | MM | IN | MM | IN | MM | ||||
| MD-TPS16TIU-2 | 16 | 1.31 | 2 | 7/19.2 | 0.015 | 0.38 | 0.045 | 1.14 | 0.43 | 10.92 | 2PR 16AWG Type N |
| MD-TPS18TIU-1 | 18 | .82 | 1 | 7/15.2 | 0.015 | 0.38 | 0.045 | 1.14 | 0.27 | 6.86 | 1PR 18AWG Type N |
| MD-TPS18TIU-2 | 18 | .82 | 2 | 7/15.2 | 0.015 | 0.38 | 0.045 | 1.14 | 0.39 | 9.91 | 2PR 18AWG Type N |
| MD-TPS18TIU-3 | 18 | .82 | 3 | 7/15.2 | 0.015 | 0.38 | 0.045 | 1.14 | 0.42 | 10.67 | 3PR 18AWG Type N |
| MD-TPS18TIU-8 | 18 | .82 | 8 | 7/15.2 | 0.015 | 0.38 | 0.06 | 1.52 | 0.62 | 15.75 | 8PR 18AWG Type N |
Applications
Cobra’s Type T/N 600 volt cables are suitable for use in commercial marine applications where flame retardant cables having excellent physical and electrical properties are required. The insulation system has a continuous operating temperature of 90°C.
Features
- IEEE & ABS APPROVED
Construction
- CONDUCTORS - Soft annealed bare copper per ASTM B3 and B8, stranded as shown.
- INSULATION - Type T/N polyvinyl chloride/nylon meeting specification IEEE 45 (1998), IEEE 1580 (2001) and UL1309/CSA 245. Thickness as shown. Insulated conductors are rated VW-1.
- PAIR SHIELD - Aluminum/polyester tape with tinned copper drain wire to provide 100% coverage over twisted pair, covered with a polyester tape.
- JACKET - Flame retardant thermoplastic polyvinyl chloride (PVC) is applied over the cable core, (covered with a polyester separator tape) and complies with Type T polyvinyl chloride as required in IEEE 45 (1998) and UL 1309/CSA 245.
![]() |
![]() |
![]() |
![]() |
|
UL Listed |
CSA |
ABS Approved |
IEEE |
RoHS Compliant |