Data Center Power Cable

Extra Flexible Power Supply Systems Cable



WARNING: California Proposition 65 - Cancer and Reproductive Harm
www.P65Warnings.ca.gov


Part
Number
Size Stranding
*
Insulation Nominal OD UL Style
**
AMPS Weight
AWG MM2 IN MM IN MM *** **** LBs/MFT KGs/Meter
A2110B 1/0 53.5 1064 X 30 0.080 2.03 0.575 14.61 1232-1284-10269 260 170 450 0.670
A2120B 2/0 67.4 1330 X 30 0.080 2.03 0.610 15.49 1232-1284-10269 300 195 551 0.820
A2130B 3/0 85.0 1665 X 30 0.080 2.03 0.685 17.40 1232-1284-10269 350 225 672 1.000
A2140B 4/0 107 2109 X 30 0.080 2.03 0.745 18.92 1232-1284-10269 405 260 820 1.220
AT250MB 250 MCM 127 2527 X 30 0.100 2.54 0.835 21.21 1284-1339-10269 455 290 951 1.415
A1350MB 350 MCM 177 3458 X 30 0.100 2.54 0.965 24.51 1284-1339-10269 570 350 1,280 1.905
A1530MB 500 MCM 253 5054 X 30 0.100 2.54 1.130 28.70 1284-1339-10269 700 430 1,868 2.780
A1750MB 750 MCM 380 7448 X 30 0.115 2.92 1.380 35.05 1284-10269 855 535 2,719 4.046
* Extra flexible conductor with soft drawn bare copper to ASTM Specifications B172.
** 1/0 AWG thru 4/0 AWG also UL 1338 & UL 10070.
*** Ampacities based on single conductor in free air, 90°C conductor temperature and 30°C ambient air temperature per NEC table 310-17.
**** Ampacities based on not more than 3 current carrying conductors in a raceway in free air, 90°C conductor temperature and 30°C ambient air temperature based on NEC table 310-16.

 

Specifications

Cobra’s Data Center Cable allows you to utilize the same cable for battery strings, internal equipment wiring, and running cable in building code installations. Cobra’s unique product has multiple approvals that include all of these unique applications and more. In addition it is competitively priced and stocked in all sizes at all of our locations. If you look at the wiring in the equipment you are installing, there is a good chance you will find Cobra cable.

 

Insulation

This product offers a unique flame retardant polyvinyl chloride compound (VW-1), and is moisture, sunlight, abrasion, acid, diesel fuel and oil resistant. It is extremely flexible and easy to work with.

 

Features

  • 105°C - 600/1000 Volt
  • "CT" Approved (Sizes 1/0 AWG through 750 MCM)
  • FT4 Rated (Sizes 1/0 AWG through 500 MCM)
  • Multiple Approvals
  • Available in Bare Copper Stranding

 

ul listed ul recognized csa nec rohs
UL Listed UL Recognized CSA NEC Types Rohs Compliant
MTW or THW
BC-5W2
Style 1232
Style 1283
Style 1284
Style 1339
Style 10070
Style 10269
TEW A/B FT-1 on 1/0 AWG to 4/0 AWG
AWM A/B FT-1 on 250 MCM to 750 MCM
MTW & THW